Get Adobe Flash player

J-Y (St) … Lg

tip-j-y
Тype: J-Y (St) … Lg
Standard: DIN VDE 0815
Construction: Copper conductors, class1 according to HD383, IEC60228, DIN VDE 0295.
Insulation,  PVC YI2  according to DIN VDE 007
Stranding  in pairs accoreding to DIN VDE 0207
Core wrapped with plastic foil
Copper drain wire
Electrostatic screen (St) of aluminium foil with drain wire
Sheath, PVC YM1 according to ,DIN VDE 0207
Application: For telecom purposes(telephone stations, for signal and data transmission). Static screening (St) protects the transmission circuits against external interference. This cable is preferably  used in dry and wet places. Use as power cable is proxibited.
Technical data: Nominal Voltage max 300 V
Temperature range: using from -30°C to +70°C  laying from -5°C to +50°C
Test voltage: [email protected]
Minimum bending radius aprox.7.5 x diameter of cable
Packaging: On coils in length of 250 meters
Standard colors: Gray
CE This product is in compilance with Low Voltage Directive 2006/95/EC
RoHS rohs-logo This product is in compilance with  Restriction of Hazardous Substances Directive 2002/95/EC 

Cross-section (mm²)

Cross-section (mm²)

1x2x0.6/0.8

8x2x0.6/0.8

2x2x0.6/0.8

12x2x0.6/0.8

3x2x0.6/0.8

16x2x0.6/0.8

4x2x0.6/0.8

20x2x0.6/0.8

5x2x0.6/0.8

24x2x0.6/0.8

6x2x0.6/0.8

30x2x0.6/0.8